A lightweight SCL function block for Siemens S7-1200/1500 to control WLED controllers via UDP. 🔌
- Smart Update: Sends data only on change or 1s heartbeat to save bandwidth. 🔄
- Color Table: Uses 20 pre-defined industrial colors for consistent signaling. 🚦
- Level Support: Optimized for WLED "Percent" effect (ID 98). 📈
- Robust: Integrated array bound checks to prevent CPU stops. 🛡️
- PLC: S7-1200 or S7-1500.
- WLED: ESP8266/ESP32 with WLED Firmware.
Import udtWledCtrl.udt and fbWledCtrl.scl. Use the TriggerSend output to drive a TSEND block.

✍️ Author G. Jacob | Automation Engineering 🛠️