add TOF channel in TPC timeseries #14945
Open
+5
−4
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Dear @miranov25 ,
if you agree I added the info about tof channel inside the sector (short).
This would help to check the calibration quality vs electronic modules and potentially to have a look to timewalk effect (time correlation with position inside the pad -> which requires mapping on electronics)
I hope I did everything correct but if you have any comment let me know.
Best,