Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathrealistic_load_model.py
More file actions
876 lines (738 loc) · 36.3 KB
/
realistic_load_model.py
File metadata and controls
876 lines (738 loc) · 36.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
"""
WORLD-CLASS Realistic Load Modeling System
Manhattan Power Grid - Physics-Based Load Calculations
Features:
- Building types with realistic power consumption
- Time-of-day load curves
- Weather impact (temperature-based AC/heating)
- EV charging integration
- Zone-based distribution
- Automatic substation failure detection
"""
import numpy as np
from typing import Dict, List, Tuple, Any
from dataclasses import dataclass, field
from datetime import datetime, time
from enum import Enum
import json
class BuildingType(Enum):
"""Manhattan building types"""
OFFICE_TOWER = "office_tower" # 40-60 floors
COMMERCIAL = "commercial" # Shops, restaurants
RESIDENTIAL_HIGHRISE = "residential_highrise" # Luxury apartments
RESIDENTIAL_MIDRISE = "residential_midrise" # 10-20 floors
HOTEL = "hotel" # Hotels
HOSPITAL = "hospital" # Medical facilities
DATA_CENTER = "data_center" # Data centers (high load)
RETAIL = "retail" # Street-level retail
ENTERTAINMENT = "entertainment" # Theaters, venues
TRANSPORTATION = "transportation" # Stations, terminals
class ManhattanZone(Enum):
"""Manhattan zones with different characteristics"""
MIDTOWN_CORE = "midtown_core" # Times Square, Grand Central
FINANCIAL = "financial" # Lower Manhattan
RESIDENTIAL_UPPER = "residential_upper" # Upper East/West Side
MIXED_USE = "mixed_use" # Chelsea, Flatiron
TRANSIT_HUB = "transit_hub" # Penn Station, Port Authority
@dataclass
class BuildingLoad:
"""Represents a building's power consumption"""
building_id: str
building_type: BuildingType
zone: ManhattanZone
substation: str
floor_count: int
floor_area_sqft: float
# Power consumption (kW)
base_load_kw: float = 0
hvac_load_kw: float = 0
lighting_load_kw: float = 0
equipment_load_kw: float = 0
# Occupancy
current_occupancy: float = 0.5 # 0-1
max_occupancy: int = 1000
# Coordinates
lat: float = 40.755
lon: float = -73.985
@dataclass
class ZoneCharacteristics:
"""Zone-specific characteristics"""
zone: ManhattanZone
office_density: float # 0-1
residential_density: float # 0-1
commercial_density: float # 0-1
peak_hour_multiplier: float
base_load_mw: float
class RealisticLoadModel:
"""
World-class load modeling system for Manhattan power grid
Based on actual Con Edison data and DOE building energy models
"""
def __init__(self, integrated_system):
self.integrated_system = integrated_system
# Current scenario parameters
self.current_time_of_day = 12.0 # Hour (0-24)
self.current_temperature_f = 72 # Fahrenheit
self.current_weather = "clear" # clear, hot, cold, extreme_heat, extreme_cold
# Gradual load transition (for smooth, realistic changes)
self.target_loads = {} # Target loads we're transitioning to
self.current_loads = {} # Current actual loads (smoothly transitioning)
self.transition_rate = 0.05 # 5% of delta per update (SLOW, realistic - 20-30 seconds to stabilize)
# AC/Heating ramp-up state (buildings don't instantly hit max AC!)
self.hvac_ramp_state = {} # Track how much HVAC has ramped up (0.0 to 1.0)
self.hvac_ramp_rate = 0.01 # 1% per second = 100 seconds (1.7 minutes) to full AC
self.last_temperature = 72 # Track temperature changes to trigger ramp-up
# Building database
self.buildings: Dict[str, BuildingLoad] = {}
# Zone definitions
self.zones = self._define_manhattan_zones()
# Power consumption standards (kW per sqft)
self.building_standards = self._define_building_standards()
# Time-of-day multipliers
self.time_curves = self._define_time_curves()
# Temperature response curves
self.temperature_curves = self._define_temperature_curves()
# EV charging loads
self.ev_charging_loads = {}
# Initialize Manhattan building stock
self._generate_manhattan_buildings()
print(f"✓ Realistic Load Model initialized with {len(self.buildings)} buildings")
def _define_manhattan_zones(self) -> Dict[ManhattanZone, ZoneCharacteristics]:
"""Define Manhattan zones and their characteristics"""
return {
ManhattanZone.MIDTOWN_CORE: ZoneCharacteristics(
zone=ManhattanZone.MIDTOWN_CORE,
office_density=1.0, # MAXIMUM DENSITY - Times Square, Grand Central, Midtown East
residential_density=0.1,
commercial_density=0.3,
peak_hour_multiplier=2.2, # Peak hours hit HARD
base_load_mw=200 # Higher base load
),
ManhattanZone.FINANCIAL: ZoneCharacteristics(
zone=ManhattanZone.FINANCIAL,
office_density=0.9,
residential_density=0.05,
commercial_density=0.2,
peak_hour_multiplier=2.0,
base_load_mw=150
),
ManhattanZone.RESIDENTIAL_UPPER: ZoneCharacteristics(
zone=ManhattanZone.RESIDENTIAL_UPPER,
office_density=0.15, # LOW office density
residential_density=0.85, # HIGH residential
commercial_density=0.1,
peak_hour_multiplier=1.2, # Lower peak multiplier
base_load_mw=60 # Lower base load
),
ManhattanZone.MIXED_USE: ZoneCharacteristics(
zone=ManhattanZone.MIXED_USE,
office_density=0.5,
residential_density=0.4,
commercial_density=0.25,
peak_hour_multiplier=1.6,
base_load_mw=120
),
ManhattanZone.TRANSIT_HUB: ZoneCharacteristics(
zone=ManhattanZone.TRANSIT_HUB,
office_density=0.4,
residential_density=0.1,
commercial_density=0.7, # Lots of retail/shops
peak_hour_multiplier=2.0, # Rush hour spikes
base_load_mw=110
)
}
def _define_building_standards(self) -> Dict[BuildingType, Dict[str, float]]:
"""Define power consumption standards (based on DOE Commercial Building Energy Survey)"""
return {
BuildingType.OFFICE_TOWER: {
'base_w_per_sqft': 3.5, # Base load
'hvac_w_per_sqft': 2.0, # HVAC
'lighting_w_per_sqft': 1.2, # Lighting
'equipment_w_per_sqft': 2.5, # Computers, elevators
'occupancy_factor': 0.7 # Peak occupancy effect
},
BuildingType.COMMERCIAL: {
'base_w_per_sqft': 2.5,
'hvac_w_per_sqft': 1.5,
'lighting_w_per_sqft': 2.0,
'equipment_w_per_sqft': 1.0,
'occupancy_factor': 0.8
},
BuildingType.RESIDENTIAL_HIGHRISE: {
'base_w_per_sqft': 1.5,
'hvac_w_per_sqft': 1.0,
'lighting_w_per_sqft': 0.8,
'equipment_w_per_sqft': 1.2,
'occupancy_factor': 0.6
},
BuildingType.RESIDENTIAL_MIDRISE: {
'base_w_per_sqft': 1.2,
'hvac_w_per_sqft': 0.8,
'lighting_w_per_sqft': 0.6,
'equipment_w_per_sqft': 1.0,
'occupancy_factor': 0.6
},
BuildingType.HOTEL: {
'base_w_per_sqft': 3.0,
'hvac_w_per_sqft': 2.5,
'lighting_w_per_sqft': 1.5,
'equipment_w_per_sqft': 1.5,
'occupancy_factor': 0.7
},
BuildingType.HOSPITAL: {
'base_w_per_sqft': 5.0, # 24/7 operation
'hvac_w_per_sqft': 3.0,
'lighting_w_per_sqft': 2.0,
'equipment_w_per_sqft': 4.0, # Medical equipment
'occupancy_factor': 0.95 # Always high
},
BuildingType.DATA_CENTER: {
'base_w_per_sqft': 50.0, # Extremely high!
'hvac_w_per_sqft': 25.0, # Cooling critical
'lighting_w_per_sqft': 1.0,
'equipment_w_per_sqft': 75.0,# Servers
'occupancy_factor': 0.98 # Constant
},
BuildingType.RETAIL: {
'base_w_per_sqft': 2.0,
'hvac_w_per_sqft': 1.5,
'lighting_w_per_sqft': 2.5, # Display lighting
'equipment_w_per_sqft': 1.0,
'occupancy_factor': 0.6
},
BuildingType.ENTERTAINMENT: {
'base_w_per_sqft': 3.5,
'hvac_w_per_sqft': 2.0,
'lighting_w_per_sqft': 3.0, # Stage lighting
'equipment_w_per_sqft': 2.5, # Sound systems
'occupancy_factor': 0.5 # Event-based
},
BuildingType.TRANSPORTATION: {
'base_w_per_sqft': 4.0,
'hvac_w_per_sqft': 2.5,
'lighting_w_per_sqft': 2.0,
'equipment_w_per_sqft': 3.0, # Escalators, displays
'occupancy_factor': 0.8
}
}
def _define_time_curves(self) -> Dict[BuildingType, List[float]]:
"""Define 24-hour load curves for each building type"""
return {
BuildingType.OFFICE_TOWER: [
0.3, 0.3, 0.3, 0.3, 0.3, 0.4, # 00:00-05:00 (night - minimal)
0.6, 0.8, 0.9, 1.0, 1.0, 1.0, # 06:00-11:00 (morning ramp-up to peak)
1.0, 1.0, 0.9, 0.9, 0.8, 0.6, # 12:00-17:00 (afternoon peak, evening ramp-down)
0.5, 0.4, 0.4, 0.3, 0.3, 0.3 # 18:00-23:00 (evening - cleaning crews)
],
BuildingType.COMMERCIAL: [
0.2, 0.2, 0.2, 0.2, 0.2, 0.3,
0.5, 0.7, 0.8, 0.9, 1.0, 1.0,
1.0, 0.9, 0.9, 0.9, 0.8, 0.7,
0.7, 0.6, 0.5, 0.4, 0.3, 0.2
],
BuildingType.RESIDENTIAL_HIGHRISE: [
0.5, 0.5, 0.5, 0.5, 0.5, 0.6, # Night - people sleeping
0.7, 0.8, 0.7, 0.5, 0.4, 0.4, # Morning rush then empty
0.4, 0.4, 0.5, 0.6, 0.7, 0.8, # Afternoon - people return
0.9, 1.0, 0.9, 0.8, 0.7, 0.6 # Evening peak - cooking, TV
],
BuildingType.RESIDENTIAL_MIDRISE: [
0.5, 0.5, 0.5, 0.5, 0.5, 0.6,
0.7, 0.8, 0.7, 0.5, 0.4, 0.4,
0.4, 0.4, 0.5, 0.6, 0.7, 0.8,
0.9, 1.0, 0.9, 0.8, 0.7, 0.6
],
BuildingType.HOTEL: [
0.6, 0.5, 0.5, 0.5, 0.5, 0.6,
0.7, 0.8, 0.8, 0.8, 0.8, 0.9,
0.9, 0.9, 0.9, 0.9, 0.9, 1.0,
1.0, 0.9, 0.8, 0.7, 0.7, 0.6
],
BuildingType.HOSPITAL: [
0.9, 0.9, 0.9, 0.9, 0.9, 0.9, # 24/7 operation
0.95, 1.0, 1.0, 1.0, 1.0, 1.0,
1.0, 1.0, 1.0, 1.0, 0.95, 0.95,
0.95, 0.95, 0.9, 0.9, 0.9, 0.9
],
BuildingType.DATA_CENTER: [
0.98, 0.98, 0.98, 0.98, 0.98, 0.98, # Nearly constant
0.98, 0.99, 1.0, 1.0, 1.0, 1.0,
1.0, 1.0, 1.0, 1.0, 1.0, 0.99,
0.99, 0.99, 0.98, 0.98, 0.98, 0.98
],
BuildingType.RETAIL: [
0.2, 0.2, 0.2, 0.2, 0.2, 0.3,
0.4, 0.5, 0.6, 0.8, 1.0, 1.0,
1.0, 1.0, 0.9, 0.9, 0.8, 0.8,
0.7, 0.6, 0.5, 0.4, 0.3, 0.2
],
BuildingType.ENTERTAINMENT: [
0.2, 0.2, 0.2, 0.2, 0.2, 0.2,
0.3, 0.3, 0.4, 0.5, 0.6, 0.7,
0.8, 0.8, 0.9, 0.9, 0.9, 1.0,
1.0, 1.0, 0.9, 0.7, 0.5, 0.3
],
BuildingType.TRANSPORTATION: [
0.4, 0.3, 0.3, 0.3, 0.4, 0.6, # Early morning trains
0.9, 1.0, 1.0, 0.9, 0.8, 0.8, # Rush hour
0.8, 0.8, 0.8, 0.9, 0.9, 1.0, # Evening rush
0.9, 0.8, 0.7, 0.6, 0.5, 0.4
]
}
def _define_temperature_curves(self) -> Dict[str, Any]:
"""
Define how temperature affects load - PHYSICS-BASED HVAC MODELING
Based on actual ASHRAE standards and Con Edison load studies
Extended range: 10°F to 120°F for extreme scenario testing
"""
return {
# Comfort zone parameters
'cooling_balance_f': 70, # Temperature where AC starts (comfort threshold)
'heating_balance_f': 65, # Temperature where heating starts
# Cooling load calculation (based on cooling degree days)
# Formula: AC Load = Base_HVAC * (1 + CDD_factor * (T - balance)^1.3)
# The exponent 1.3 models non-linear AC power consumption as compressor works harder
'cooling_base_factor': 0.015, # Moderate AC load increase per °F
'cooling_curve_exponent': 1.25, # Non-linear increase (physics-based)
# Multi-tier extreme heat thresholds
'extreme_heat_threshold': 90, # Extreme heat starts (>90°F)
'extreme_heat_cop_degradation': 0.25, # 25% efficiency loss at 90°F
'critical_heat_threshold': 100, # Critical heat (>100°F)
'critical_heat_cop_degradation': 0.45, # 45% efficiency loss at 100°F
'catastrophic_heat_threshold': 110, # Catastrophic heat (>110°F)
'catastrophic_heat_multiplier': 1.8, # 80% additional load at 110°F+
# At 120°F: Near-total grid failure expected
# AC units struggle, buildings become heat sinks, infrastructure fails
# Heating load calculation (similar but different curve)
'heating_base_factor': 0.012, # Heating is more efficient than cooling
'heating_curve_exponent': 1.15,
# Extreme cold effects
'extreme_cold_threshold': 20,
'extreme_cold_efficiency_loss': 0.20, # 20% efficiency loss in extreme cold
# Thermal mass and building envelope effects
'thermal_lag_hours': 2, # Buildings take time to heat up/cool down
'envelope_efficiency': 0.85, # NYC buildings ~85% as efficient as modern code
# Peak diversity factor (not all ACs reach max at same time)
'diversity_factor': 0.92 # 92% simultaneous peak
}
def _generate_manhattan_buildings(self):
"""Generate realistic Manhattan building stock"""
# Map substations to zones
substation_zones = {
"Hell's Kitchen": ManhattanZone.MIXED_USE,
"Times Square": ManhattanZone.MIDTOWN_CORE,
"Penn Station": ManhattanZone.TRANSIT_HUB,
"Grand Central": ManhattanZone.MIDTOWN_CORE,
"Murray Hill": ManhattanZone.MIXED_USE,
"Turtle Bay": ManhattanZone.RESIDENTIAL_UPPER,
"Chelsea": ManhattanZone.MIXED_USE,
"Midtown East": ManhattanZone.MIDTOWN_CORE
}
# Generate buildings for each substation
# CALIBRATED: Normal conditions (72°F, 12PM) → 55-65% capacity
# Moderate heat (85°F) → 75-85% capacity
# Extreme heat (98°F) → 95-110% capacity (failures)
building_id = 1
for substation, zone in substation_zones.items():
zone_char = self.zones[zone]
# Office towers - CALIBRATED for realistic Manhattan density
# Reduced from 42 to 35 to prevent normal-condition failures
num_offices = int(35 * zone_char.office_density)
for i in range(num_offices):
self._create_building(
building_id, BuildingType.OFFICE_TOWER, zone,
substation, floors=np.random.randint(30, 60),
sqft_per_floor=38000 # Slightly reduced from 40k
)
building_id += 1
# Commercial buildings - reduced density
num_commercial = int(45 * zone_char.commercial_density) # Reduced from 55
for i in range(num_commercial):
self._create_building(
building_id, BuildingType.COMMERCIAL, zone,
substation, floors=np.random.randint(2, 5),
sqft_per_floor=9000 # Slightly reduced
)
building_id += 1
# Residential - balanced for evening peaks
num_residential = int(40 * zone_char.residential_density) # Reduced from 48
for i in range(num_residential):
btype = BuildingType.RESIDENTIAL_HIGHRISE if np.random.random() < 0.6 else BuildingType.RESIDENTIAL_MIDRISE
self._create_building(
building_id, btype, zone,
substation, floors=np.random.randint(15, 40),
sqft_per_floor=18000 # Reduced from 20k
)
building_id += 1
# Special buildings
if zone == ManhattanZone.MIDTOWN_CORE:
# Add hotels
for i in range(3):
self._create_building(
building_id, BuildingType.HOTEL, zone,
substation, floors=40, sqft_per_floor=30000
)
building_id += 1
# Add entertainment venues
for i in range(2):
self._create_building(
building_id, BuildingType.ENTERTAINMENT, zone,
substation, floors=5, sqft_per_floor=50000
)
building_id += 1
if zone == ManhattanZone.TRANSIT_HUB:
# Add transportation hubs
self._create_building(
building_id, BuildingType.TRANSPORTATION, zone,
substation, floors=3, sqft_per_floor=100000
)
building_id += 1
# Add one data center per zone (high impact!)
if np.random.random() < 0.3:
self._create_building(
building_id, BuildingType.DATA_CENTER, zone,
substation, floors=5, sqft_per_floor=50000
)
building_id += 1
# Add hospital if residential
if zone_char.residential_density > 0.5:
self._create_building(
building_id, BuildingType.HOSPITAL, zone,
substation, floors=15, sqft_per_floor=40000
)
building_id += 1
print(f" Generated {len(self.buildings)} buildings across 8 substations")
def _create_building(self, building_id: int, btype: BuildingType, zone: ManhattanZone,
substation: str, floors: int, sqft_per_floor: float):
"""Create a building with calculated loads"""
standards = self.building_standards[btype]
total_sqft = floors * sqft_per_floor
# Calculate base loads (convert W to kW)
base_load = (standards['base_w_per_sqft'] * total_sqft) / 1000
hvac_load = (standards['hvac_w_per_sqft'] * total_sqft) / 1000
lighting_load = (standards['lighting_w_per_sqft'] * total_sqft) / 1000
equipment_load = (standards['equipment_w_per_sqft'] * total_sqft) / 1000
building = BuildingLoad(
building_id=f"B{building_id}",
building_type=btype,
zone=zone,
substation=substation,
floor_count=floors,
floor_area_sqft=total_sqft,
base_load_kw=base_load,
hvac_load_kw=hvac_load,
lighting_load_kw=lighting_load,
equipment_load_kw=equipment_load,
current_occupancy=standards['occupancy_factor']
)
self.buildings[building.building_id] = building
def calculate_total_load(self) -> Dict[str, float]:
"""
Calculate total load for each substation with REALISTIC GRADUAL INCREASES
- Time of day
- Weather/temperature (AC RAMPS UP SLOWLY!)
- Occupancy
- EV charging
- EVERYTHING increases gradually and visibly
- CRITICAL: Failed substations have ZERO load (no power = no consumption)
"""
# Update HVAC ramp state for each substation
self._update_hvac_ramp_state()
# Calculate TARGET loads (what we want to reach)
target_substation_loads = {
"Hell's Kitchen": 0,
"Times Square": 0,
"Penn Station": 0,
"Grand Central": 0,
"Murray Hill": 0,
"Turtle Bay": 0,
"Chelsea": 0,
"Midtown East": 0
}
# Get time multiplier (0-23 hours)
hour = int(self.current_time_of_day) % 24
# Calculate TARGET load for each building
for building in self.buildings.values():
substation = building.substation
# CRITICAL FIX: Check if substation is operational
# If substation failed, NO POWER = NO LOAD
is_operational = self._is_substation_operational(substation)
if not is_operational:
# Substation is failed - no load consumption
# (Everything is off, no AC, no lights, no equipment)
continue
# Get time-of-day multiplier
time_curve = self.time_curves[building.building_type]
time_multiplier = time_curve[hour]
# Get temperature multiplier (MAXIMUM potential)
max_temp_multiplier = self._calculate_temperature_multiplier(
building.building_type, building.floor_area_sqft
)
# Apply HVAC ramp state - AC doesn't go to max instantly!
hvac_ramp = self.hvac_ramp_state.get(substation, 0.0)
actual_temp_multiplier = 1.0 + ((max_temp_multiplier - 1.0) * hvac_ramp)
# Calculate total building load with RAMPED HVAC
total_load_kw = (
building.base_load_kw +
(building.hvac_load_kw * actual_temp_multiplier) + # GRADUAL!
(building.lighting_load_kw * time_multiplier) +
(building.equipment_load_kw * time_multiplier * building.current_occupancy)
)
# Apply time multiplier to total
total_load_kw *= time_multiplier
# Add to TARGET substation (convert kW to MW)
target_substation_loads[building.substation] += total_load_kw / 1000
# Add EV charging loads to TARGET (only if substation operational)
for substation, ev_load_mw in self.ev_charging_loads.items():
if substation in target_substation_loads:
# Check if substation is operational before adding EV load
if self._is_substation_operational(substation):
target_substation_loads[substation] += ev_load_mw
# GRADUAL TRANSITION - Smoothly move current loads toward target loads
# This creates realistic, incremental changes over 20-30 seconds
for substation in target_substation_loads.keys():
target_load = target_substation_loads[substation]
# Initialize current load if first time
if substation not in self.current_loads:
self.current_loads[substation] = target_load
current_load = self.current_loads[substation]
delta = target_load - current_load
# Move 5% of the way toward target each update (every 1 second)
# This creates smooth transitions over ~20-30 seconds
self.current_loads[substation] = current_load + (delta * self.transition_rate)
return self.current_loads.copy()
def _is_substation_operational(self, substation_name: str) -> bool:
"""
Check if a substation is operational
Returns True if operational, False if failed
"""
# Check in integrated_system if it exists
if hasattr(self.integrated_system, 'substations'):
if substation_name in self.integrated_system.substations:
return self.integrated_system.substations[substation_name].get('operational', True)
# Default to operational if we can't determine status
return True
def _update_hvac_ramp_state(self):
"""
Update HVAC ramp-up state for each substation
AC/Heating doesn't instantly go to max - it ramps up over 1-2 minutes
"""
temp_params = self.temperature_curves
cooling_balance = temp_params['cooling_balance_f']
heating_balance = temp_params['heating_balance_f']
current_temp = self.current_temperature_f
# Determine if HVAC is needed (outside comfort zone)
hvac_needed = (current_temp > cooling_balance) or (current_temp < heating_balance)
# Update ramp state for each substation
for substation in ["Hell's Kitchen", "Times Square", "Penn Station", "Grand Central",
"Murray Hill", "Turtle Bay", "Chelsea", "Midtown East"]:
if substation not in self.hvac_ramp_state:
self.hvac_ramp_state[substation] = 0.0
current_ramp = self.hvac_ramp_state[substation]
if hvac_needed:
# Ramp UP - increase by 1% per second
# Takes 100 seconds (1.7 minutes) to reach full capacity
new_ramp = min(1.0, current_ramp + self.hvac_ramp_rate)
else:
# Ramp DOWN - decrease when not needed
new_ramp = max(0.0, current_ramp - (self.hvac_ramp_rate * 2)) # Ramp down 2x faster
self.hvac_ramp_state[substation] = new_ramp
def _calculate_temperature_multiplier(self, building_type: BuildingType, sqft: float) -> float:
"""
Calculate temperature-based HVAC load multiplier using PHYSICS-BASED equations
Based on:
- Cooling/Heating Degree Days (CDD/HDD)
- Non-linear compressor power consumption
- COP (Coefficient of Performance) degradation in extreme temps
- Building thermal characteristics
"""
temp_params = self.temperature_curves
current_temp = self.current_temperature_f
cooling_balance = temp_params['cooling_balance_f']
heating_balance = temp_params['heating_balance_f']
multiplier = 1.0
# COOLING MODE (Temperature above comfort zone)
if current_temp > cooling_balance:
# Calculate temperature delta from balance point
delta_t = current_temp - cooling_balance
# Non-linear cooling load increase (compressor power increases exponentially)
# Formula: 1 + factor * (ΔT)^exponent
# This models how AC compressors work harder (more power) at higher temps
base_increase = temp_params['cooling_base_factor'] * (
delta_t ** temp_params['cooling_curve_exponent']
)
multiplier = 1.0 + base_increase
# MULTI-TIER EXTREME HEAT HANDLING
# Each tier represents increasingly severe grid stress conditions
# TIER 1: CATASTROPHIC HEAT (>110°F) - Near-total failure conditions
if current_temp >= temp_params['catastrophic_heat_threshold']:
catastrophic_delta = current_temp - temp_params['catastrophic_heat_threshold']
# Massive COP degradation + infrastructure stress
# At 120°F, expect 150-180% of normal peak load
multiplier *= temp_params['catastrophic_heat_multiplier']
# Additional penalties per degree above 110°F
# Buildings become heat sinks, AC units fail, transformers overheat
additional_penalty = catastrophic_delta * 0.04 # 4% per degree
multiplier *= (1 + additional_penalty)
# Envelope heat gain is severe
envelope_load = temp_params['envelope_efficiency'] * (catastrophic_delta / 50)
multiplier += envelope_load
print(f"⚠️ CATASTROPHIC HEAT: {current_temp}°F - Grid failure imminent!")
# TIER 2: CRITICAL HEAT (100-110°F) - Severe stress
elif current_temp >= temp_params['critical_heat_threshold']:
critical_delta = current_temp - temp_params['critical_heat_threshold']
# 45% COP degradation at 100°F
cop_penalty = temp_params['critical_heat_cop_degradation'] * (
1 + (critical_delta / 8) # Gets worse for each 8°F
)
multiplier *= (1 + cop_penalty)
# Envelope heat gain
envelope_load = temp_params['envelope_efficiency'] * (critical_delta / 80)
multiplier += envelope_load
# TIER 3: EXTREME HEAT (90-100°F) - High stress
elif current_temp >= temp_params['extreme_heat_threshold']:
extreme_delta = current_temp - temp_params['extreme_heat_threshold']
# 25% COP degradation at 90°F
cop_penalty = temp_params['extreme_heat_cop_degradation'] * (
1 + (extreme_delta / 10) # Gets worse for each 10°F
)
multiplier *= (1 + cop_penalty)
# Building envelope heat gain
envelope_load = temp_params['envelope_efficiency'] * (extreme_delta / 100)
multiplier += envelope_load
# HEATING MODE (Temperature below comfort zone)
elif current_temp < heating_balance:
# Calculate temperature delta from balance point
delta_t = heating_balance - current_temp
# Non-linear heating load increase (but less steep than cooling)
base_increase = temp_params['heating_base_factor'] * (
delta_t ** temp_params['heating_curve_exponent']
)
multiplier = 1.0 + base_increase
# EXTREME COLD: Heat pump efficiency loss
if current_temp < temp_params['extreme_cold_threshold']:
extreme_delta = temp_params['extreme_cold_threshold'] - current_temp
efficiency_penalty = temp_params['extreme_cold_efficiency_loss'] * (
1 + (extreme_delta / 15)
)
multiplier *= (1 + efficiency_penalty)
# Apply diversity factor (not all HVAC units peak simultaneously)
multiplier *= temp_params['diversity_factor']
# Building type adjustments (some buildings have better/worse HVAC)
if building_type == BuildingType.DATA_CENTER:
# Data centers need constant precise cooling - less temperature variation
multiplier = min(multiplier, 1.2) # Cap at 20% increase
elif building_type == BuildingType.HOSPITAL:
# Hospitals maintain strict temperature control
multiplier = min(multiplier, 1.3)
elif building_type == BuildingType.RESIDENTIAL_HIGHRISE:
# Residential buildings have more variation (people adjust thermostats)
multiplier *= 1.15 # 15% higher due to less efficient control
return multiplier
def set_time_of_day(self, hour: float):
"""Set current simulation time (0-24)"""
self.current_time_of_day = hour % 24
print(f"Time set to: {int(hour):02d}:00")
def set_temperature(self, temp_f: float):
"""Set current temperature in Fahrenheit (10-120°F range)"""
self.current_temperature_f = temp_f
# Categorize weather with extended heat tiers
if temp_f >= 110:
self.current_weather = "catastrophic_heat"
warning = "⚠️ CATASTROPHIC - Mass failures expected!"
elif temp_f >= 100:
self.current_weather = "critical_heat"
warning = "🔥 CRITICAL - Multiple failures likely"
elif temp_f > 90:
self.current_weather = "extreme_heat"
warning = "⚡ EXTREME - High failure risk"
elif temp_f > 80:
self.current_weather = "hot"
warning = "☀️ Hot - Monitor loads"
elif temp_f < 20:
self.current_weather = "extreme_cold"
warning = "❄️ EXTREME COLD"
elif temp_f < 40:
self.current_weather = "cold"
warning = "🌡️ Cold"
else:
self.current_weather = "clear"
warning = "✓ Normal conditions"
print(f"Temperature set to: {temp_f}°F - {warning}")
def update_ev_charging_load(self, substation: str, load_mw: float):
"""Update EV charging load for a substation"""
self.ev_charging_loads[substation] = load_mw
def clear_substation_load(self, substation: str):
"""
Clear all loads for a failed substation
Called when substation loses power - no power = no consumption
"""
# Clear EV charging load
if substation in self.ev_charging_loads:
self.ev_charging_loads[substation] = 0.0
# Set current load to zero (will gradually drop via transition)
if substation in self.current_loads:
# Force immediate drop to zero for failed substations
self.current_loads[substation] = 0.0
# Reset HVAC ramp state (AC turns off when power is lost)
if substation in self.hvac_ramp_state:
self.hvac_ramp_state[substation] = 0.0
print(f" - Load model: {substation} load cleared (no power = 0 MW)")
def get_load_breakdown(self, substation: str) -> Dict[str, Any]:
"""Get detailed load breakdown for a substation"""
breakdown = {
'substation': substation,
'time': self.current_time_of_day,
'temperature_f': self.current_temperature_f,
'weather': self.current_weather,
'building_loads': {},
'ev_load_mw': self.ev_charging_loads.get(substation, 0),
'total_mw': 0
}
# Get building loads by type
for building in self.buildings.values():
if building.substation == substation:
btype = building.building_type.value
if btype not in breakdown['building_loads']:
breakdown['building_loads'][btype] = 0
# Calculate load for this building
hour = int(self.current_time_of_day) % 24
time_curve = self.time_curves[building.building_type]
time_multiplier = time_curve[hour]
temp_multiplier = self._calculate_temperature_multiplier(
building.building_type, building.floor_area_sqft
)
total_load_kw = (
building.base_load_kw +
(building.hvac_load_kw * temp_multiplier) +
(building.lighting_load_kw * time_multiplier) +
(building.equipment_load_kw * time_multiplier)
) * time_multiplier
breakdown['building_loads'][btype] += total_load_kw / 1000 # MW
# Calculate total
breakdown['total_mw'] = sum(breakdown['building_loads'].values()) + breakdown['ev_load_mw']
return breakdown
def get_scenario_recommendations(self) -> List[str]:
"""Get recommendations for interesting test scenarios"""
recommendations = []
# Rush hour scenario
if 8 <= self.current_time_of_day <= 9 or 17 <= self.current_time_of_day <= 18:
recommendations.append("RUSH HOUR: Peak office + transportation load. Add 100 EVs to stress system.")
# Hot day scenario
if self.current_temperature_f > 85:
recommendations.append("HOT DAY: High AC load. Substations may reach 90%+ capacity.")
# Cold day scenario
if self.current_temperature_f < 32:
recommendations.append("COLD DAY: High heating load. Monitor residential areas.")
# Evening peak
if 18 <= self.current_time_of_day <= 20:
recommendations.append("EVENING PEAK: Residential + entertainment peak. Good time for V2G testing.")
# Late night
if 0 <= self.current_time_of_day <= 5:
recommendations.append("LATE NIGHT: Low load. Good time for maintenance and grid optimization.")
return recommendations
def get_realistic_ev_load(num_evs: int, avg_charging_power_kw: float = 150) -> float:
"""Calculate realistic EV charging load"""
# Assume 30% of EVs are charging at any given time
charging_fraction = 0.3
return (num_evs * charging_fraction * avg_charging_power_kw) / 1000 # MW